Add to cart
Product added to the basket The stock is insufficient - units have been added to cart Total:
|
Out of stock
|
Minimum purchase quantity
The minimum purchase quantity is not reached
|
Description
NF8108M is network equipment after NF-8108. According to customers' requirement, it is updated with backlight function and 8 remote identifiers. Its main functions are: cable connection sequence, length testing, and determine any open, short circuit, jumper or cross-talk interference. It is said to be a ideal tool to prevent and solve cable installation problem.
Product features
1. One person enough to locate the wire or connection error
2. Checks wiring error in 5E, 6E, coaxial and telephone line, (open circuit, short circuit, jumper wire, reverse connection or cross-talk interference)
3. Make cable length measurement and determine the range of open circuit and short circuit
4. User can calibrate cable length dynamically and the accuracy can up to 95%.
5. Locates cable and there are 8 far-end passive test jacks (ID no.: ID1 - ID 8)
6. Easy operation, and clear test result on screen.
7. Portable unit with long battery life (wait-case 50 hours)
8. Automatically time-delay shut off
9. Self-checking function and automatically compensates any change in battery capacity or ambient temperature
Technical parameters
Overall Dimension | 180×80×40mm |
Power Supply | 4×1.5V Size AA batteries with power consumption 16mA |
Display | Special 4×16 character big screen LCD lattice (valid visual field 61.6×25.5 mm) |
Cable type | STP/UTP twin twisted cable, coaxial cable, telephone line |
Working Ambient Temperature | -10~+60 |
Tester Port |
Tester RJ45 master port(M), tester LOOPBACK RJ45 port(L), far-end Recognizer RJ45 port(R). The extra BNC and RJ11 converters are used to Measure and check the continuity of coaxial cable and telephone line. |
Length Measurement of Twin Twisted Cable |
Scope: 350M(3~200ft) Calibration accuracy:3%(±0.5M or ±.5ft)(calibrating cable≥5M) Shipment accuracy :5%(±0.5M or ±1.5ft).(AMP,AT& T Class 5 cable) |
Length Calibration |
User can set the exact length by himself based on a given length cable. And the length of cable should be more than 5M |
Wire Sequence and Locating Cable Error | Check errors such as open, short circuit, reverse connection, crossover or cross-talk interference. |
Locating Cable | 8 far-end passive test jacks (ID 1-ID 8) |
Automatic Time-delay Shut Off Time | The tester will be on standby for 30 minutes. |
Alert
Please enter the required fields! |